Winpact Parallel Fermentation System is the ultimate and true parallel system for your parallel experiment. Whether you need to run two identical experiments or different experiments at once, the duo heating system allows you to run two thermostat heating, two dry heating or one thermostat and one dry heating simultaneously. This state-of-the-art fermenter/bioreactor is constructed with the upmost versatility and flexibility to work with all types and sites of Winpact vessels. The remote control software can control up to 16 fermentors for true parallel operation.
Controller | Duo heating system controller | |||||
---|---|---|---|---|---|---|
Built-in rotameter | ||||||
4 built-in pump heads | ||||||
Vessel | Double Jacketed Dish Bottom Vessel (includes glass body, head plate, T-handling bar, 2 probe adaptors) | Single Wall Dish Bottom Vessel (includes glass body, head plate, T-handling bar, 2 probe adaptors) | Air Lifter Vessel (includes glass body, head plate, draft tube, T-handling bar, 2 probe adaptors) | Single Wall Dish Bottom Vessel with Heating Blanket (includes glass body, head plate, T-handling bar, 2 probe adaptors and heating blanket) | Single Wall Plain Bottom Vessel with Heating Base Unit (includes glass body, head plate, T-handling bar, 2 probe adaptors and heating base unit) | Solid State (FS-V-SA05P) |
Rushton-type impellers | No impellers | Rushton-type impellers | Multi-Type | |||
Baffle assembled | Draft tube assembled | Baffle assembled | N / A | |||
Condenser assembled | ||||||
Air sparger assembled | Micro sparger assembled | Air sparger assembled | ||||
Agitation motor | Brushless motor | N / A | Brushless motor | Brushless motor | ||
Probes | 1x pH probe and 1x probe cable | Optional | ||||
1x DO probe and 1x probe cable | Optional | |||||
1x Temperature probe and 1x probe cable | ||||||
1x anti-foam/level sensor and 1x probe cable | N / A | |||||
Start-up kit | Complete start-up kit includes silicone tubes, tube clamps, metal connector and autoclavable disc filters. Please see p.35 for details. |
Vessel | Double Jacketed (FS-V-A series) | Single Wall (FS-V-B series) | Air Lifter (FS-V-C series) | |||||||
---|---|---|---|---|---|---|---|---|---|---|
Working volume | 500ml | 1L | 3L | 5L | 10L | 1L | 3L | 5L | 10L | 5L |
Total volume | 1L | 1.5L | 3.8L | 6.8L | 12.5L | 1.5L | 3.8L | 6.8L | 12.5L | 7L |
Vessel | Single Wall with Heating Blanket (FS-V-B series) | Single Wall with Heating Base Unit (FS-V-D series) | |||||||
---|---|---|---|---|---|---|---|---|---|
Working volume | 1L | 3L | 5L | 10L | 15L | 20L | 3L | 5L | 10L |
Total volume | 1.5L | 3.8L | 6.8L | 12.5L | 18.7L | 23.7L | 3.7L | 6.7L | 13.1L |
*All vessels are made of borosilicate glass and 316L stainless steel for headplate and all fittings.
Power source | 210-230V, 50-60Hz with electrical safety cutoff switch |
---|---|
Water source | 0.4-1 bar (5.8-14.5 psi); water supplied to fermentors should be at least 15°C below the set operating temperature |
Air source | 0.5-2 bar, must be dry, oil-free and filtered. |
Sterilization | Autoclave; size of the autoclave's inner chamber must be able to accomodate vessel with condenser attached |
Control unit | Control panel | 10.4" Color touch-screen interface |
---|---|---|
Communication port | Remote software control through Ethernet, up to 16 systems per PC | |
Data export through USB port | ||
Analog AUX port for system extension | ||
Program storage | Up to 59,994 process programs | |
Log data storage | Up to 100 process monitoring data files | |
Cabinet material | ABS front panel and painted iron housing | |
Dimension | Footprint: W x L = 15.75" x 21.61" (400 mm x 549 mm); Height: 29.14" (740 mm) | |
Rated voltage | 220V~; 50/60 Hz, 10A, 2000W | |
Weight | Approx. 114.6 lb (52 kg) | |
Aeration | Inlet gas flow-meter | 0,0.1-1 LPM (500 ml); 0, 0.2-2.5 LPM (1 L); 0, 1-10 LPM (3, 5 L); 0, 2-25 LPM (10 L); 0, 6-50 LPM (15, 20 L) |
Sparger | L-shape (500ml, 1L); Ring sparger (3L and above); Micro-sparger (C type vessels); Center-located sparger (solid state) |
|
Baffle | 316L stainless steel baffles
|
|
Temperature | Heating | 1. Thermostat system: built-in heat exchanger (550W heater, water circulation pump) |
2. Dry heating system : external devices (heating blanket or heating base unit) | ||
Cooling | Built-in water module and external water circulator (optional) | |
Range |
|
|
Probe | Platinum RTD probe (PT-100), non autoclavable | |
Control mode | Manual or programmable 15-step PID control | |
Agitation | Drive | Removable top brushless motor |
Speed range |
|
|
Resolution | 1 rpm increment | |
Impeller |
|
|
Control mode | Manual or programmable 15-step PID control with adjustable deadband | |
pH | Range | 0 -14 (2-12 for maximum precision) |
Resolution | 0.01 pH | |
Probe | Gel-filled electrode, autoclavable | |
Control mode | Manual/acid start/progrmmable 15-step PID control | |
DO | Range | 0-200%, Control range: 0-100%, adjustable |
Resolution | 0.1% | |
Probe | Polarographic DO sensor; autoclavable | |
Control mode |
|
|
ORP (optional) | Measurement range | ± 2000 mV |
Resolution | 1 mV | |
Probe | Gel-filled electrode: autoclavable | |
Foam / level | Probe | 316L stainless steel protector with insulated PTFE tube; autoclavable, adjustable sensitivity control |
Control mode | Foam: on/off switch Level: on/off switch control with wet/dry probe set up |
|
Peristaltic pump | Pump number | 4 built-in Watson Marlow pumps per vessel (total 8); Total 4 external pumps expandable:
|
Motor type | Precise stepping motor; minimum speed is 1 rpm | |
Speed range | 0 - 65 rpm | |
Resolution | 1 rpm | |
Control mode | Manual or programmable 15-step feeding control; pump can be assigned for acid, base, antifoam and substrate | |
Exhaust | Device type | 316L stainless steel condenser |
Optional Devices and Accessories: ( Link for more info... )